Articles on
this page by Collyn Rivers
CABLE SIZE & CONVERSIONS
VOLTAGE DROP
LEAD ACID BATTERIES
WHAT SOLAR MODULES REALLY PRODUCE
Cable
Sizes & Conversions
by
Collyn Rivers
All electrical
cable resists the flow of current
and the larger the
diameter of the cable, and the shorter its length, the lower is its
resistance. It is essential to minimise this resistance because it
reduces the voltage that lights, refrigerators and other electrical
bits and pieces need to work correctly.
In practice, the
highest acceptable voltage loss in any 12/24 volt campervan or
motorhome wiring is 3% of the battery voltage. That is: 0.36 volts,
and 0.72 volts in 12 and 24 volt circuits respectively. Professional
installers often work toward 5% losses because it saves on cable
costs – but at the expense of their clients whose electric fridges
will never work as well as their makers intended.
Given that 3%
voltage drop is the maximum acceptable drop (but 1.5%-2% is better)
it should be easy enough to select cable accordingly: tables of
recommended cable sizes for various current flows are readily
available. There’s also a really simple bit of arithmetic that does
the job superbly (see below).
Auto
Cable – a Trap!
Unfortunately there’s a huge trap. Automobile cable is commonly sold
using a rating system that appears to correspond (but doesn’t) with
appliance manufacturers’ cabling recommendations. Nor does it, nor
indeed can it, correspond with other cable size standards.
Auto cable is that
cable invariably sold by auto parts stores, auto-electricians and
many hardware stores. This cable is rated in terms of its outside
diameter – insulation and all. In other words all that
measurement tells you is the size hole it can be passed through!
But most appliance
manufacturers and virtually all electrical trades specify cable
either directly in terms of the cross-sectional area (in sq.mm) of
its copper conductor - or by a numbering system (such as AWG) that
relates to conductor area.
A typically
recommended cable size is 2.5 mm.sq. Generally, the appliance maker
will spell this out in full (eg. 2.5 sq.mm) – but not invariably.
You can however be certain that if the appliance maker talks about
2.5 mm cable they refer to 2.5 sq mm cross-sectional area.
But when a
buyer fronts up to the parts store and asks for the specified 2.50
mm cable what he will almost certainly be sold is not 2.50 mm.sq.
cable, but 3.00 mm diameter auto cable (the closest made to
2.5 sq mm). A 3.0 mm diameter auto cable’s conductor area however
is typically a tad over 1.0 sq mm – about one third of the required
size
If such cable is
used for example for fridge wiring, the voltage drop across it will
be close to three times that specified as the maximum by the
appliance maker!
Unless that cable
is exceptionally short, that fridge, which may be a top brand in
perfect working order, will never work satisfactorily. This is the
main reason why so many 12-volt fridges disappoint, and why trailer
batteries are often grossly undercharged. Yet countless (in my
experience, most) trailers and motorhomes are, at least in
part, wired this way! And that includes professional installations.
Ampacity
Compounding this, automobile cable may also be rated in amps. Thus,
‘3 mm’ cable is highly likely also to be described as ’20 amp’ (the
amount of this claim varies from maker to maker). Most people not
unreasonably take this as the recommended current rating. But it’s
not.
That ’20 amp’
rating is not a recommendation of the current the cable could/should
carry. It is an indication of the highest current that cable can
carry before its insulation virtually melts (this rating is often
known as ‘ampacity’). It does not take voltage drop in to account.
Ampacity is a fire-related thing only.
How
to Choose the Right Cable
As noted
previously, appliance makers usually specify the minimum-sized cable
that may be used. Some supply the actual cable. In all cases,
heavier cable must be used if the length of cable is longer than
that specified.
But this is of no
help to someone wiring a complete vehicle. The rule here is to
assess the maximum current that will be carried by each cable run
and specify that cable size accordingly.
Tables of cable
sizes for various lengths of cable and current carrying capacity are
obtainable from cable manufacturers, are also published in books
such as my own ‘Motorhome Electrics’. I have included a simplified
version in this feature
There is a slight discrepancy in most published
conversions (mine are corrected) between the most commonly used AWG
gauges and ISO gauges. This discrepancy, due to ‘rounding up’, of
the two gauges has resulted in the general use of cables one AWG
gauge too small. To be safe, use one AWG gauge size larger (ie.
numerically lower than most conversion tables shows. Note the one
reproduced here is correct
ISO gauges are easy. The
actual gauge number (eg. 2.5, 4.0, 6.0, 10 etc) is the actual cross
sectional area, of the conductor, in mm.sq.
It is practicably
impossible to give any meaningful conversion between auto cable, AWG
or ISO. This is because the insulation thickness of auto cable
varies from vendor to vendor. Thus 4 mm auto cable can does have
conductor cross-sections from an extraordinary 1.25 sq mm – a more
typical 1.8 sq mm. A few makers supply it at 2.0 sq mm.
What can be
assumed is that 4 mm auto cable can be used instead of 1.5 sq mm
cable; 6 mm auto cable can be used instead of 4 sq mm cable, 8 mm
auto cable is almost the same as 8 sq mm. Anything smaller than 3 mm
auto cable has so little copper that it’s really only useful for
instrument wiring.
Just why
automobile cable is sold using this insane and misleading rating is
unclear. The sooner it changes the better as it has caused huge
problems for countless people for decades.
A
Better Way
As
mentioned previously is also very easy to work out the voltage drop
for any given length of cable, current flow, and cable size. I
always use this rather than published tables (including my own)
because once remembered it’s so easy to do – and it gives the right
answer every time. The formula is simply:
Voltage drop equals (cable length (in metres) X
current (in amps) X 0.017) divided by cable cross-section in mm.sq.
For example: 10 metres X 5 amps X 0.017 = 0.85.
Divided by (say) 2.5 (sq mm), the voltage drop is 0.34 volt. This is
just acceptable – but (here) 4.0 sq mm would be even better. That
results in a drop of 0.212 volts.
Cable size tables
and the above formula is for the voltage drop across a single
conductor path. Where, as is common with trailers, there’s twin
conductors (one positive, one negative) the total conductor
length must be taken into account. In other words, if there’s a five
metre run using twin cable, that’s 10 metres to be taken into
account.
The very best
cable to use for campervan and motorhome work is so-called ‘tinned’
copper. It’s not actually tinned, but rather copper electroplated
with a nickel alloy. It is obtainable from boating electrical
equipment suppliers and wholesale electrical suppliers, but is hard
to locate otherwise. It’s worth tracking down, not least because it
is available in ISO sizes.
The above is
extracted from my previously published articles and books. The theme
is greatly expanded in my book ‘Motorhome Electrics – and Caravans
Too!’ and this book is being increasingly used as a reference work
by auto electricians
Australia-wide. It is
also now being used a the basic text in this field by TAFE.
It also sells in
large numbers overseas – especially in New Zealand and the UK.
Copyright
Please note that ALL my published writing
is fully protected under the Commonwealth Copyright Act. This
article and (copyright) Table is reproduced here by express
permission from the Copyright Holders – Caravan and Motorhome Books,
Broome, WA 6725. It may not be reproduced in any shape or form, or
in any media without express permission as above.
Caravan and Motorhome Books
There is a whole heap of
information on various subjects on my website:
Caravan
and Motorhome Books by Collyn Rivers
Collyn Rivers
Broome, August 2004.
Conversion Table
|
AWG |
18 |
17 |
16 |
15 |
14 |
13 |
12 |
11 |
10 |
9 |
8 |
7 |
6 |
5 |
4 |
3 |
|
ISO |
0.75 |
1
|
|
1.5 |
|
2.5 |
|
4 |
|
6 |
|
10 |
|
16 |
|
25 |
|
Auto
Cable |
|
3 |
|
|
4 |
|
5 |
|
6 |
|
|
|
|
|
|
|
Note: this table is copyright ‘Caravan and Motorhome Books, Broome
2002.
Caravan
and Motorhome Books by Collyn Rivers
back to top

Voltage Drop
by Collyn Rivers
|
Current |
<1
metres |
<2
metres |
<3metres |
<4
metres |
<5
metres |
<6
metres |
|
5 amps |
1.0 (16) |
1.0 (16) |
1.5
(14) |
2.5 (12) |
2.5 (12) |
4.0 (10) |
|
10 amps |
1.0 (16) |
2.5 (12) |
2.5
(12) |
4.0
(10) |
6.0 (8) |
6.0 (8) |
|
15 amps |
1.5
(14) |
4.0
(10) |
6.0 (8) |
6.0 (8) |
10 (6) |
10 (6) |
|
20 amps |
2.5
(12) |
4.0 (10) |
6.0 (8) |
10 (6) |
10 (6) |
16 (4) |
|
30 amps |
4.0
(10) |
6.0 (8) |
10 (6) |
16 (4) |
16 (4) |
25 (2) |
|
50 amps |
6.0 (8) |
10 (6) |
16 (4) |
25 (2) |
25 (2) |
25 (2) |
Cable sizes for 12-volt fridge and other
circuits. The sizes, in square millimetres, (and in brackets
AWG) introduce less than 3% voltage drop at the
maximum distance in each range. In the above Table, 4 mm auto
cable can replace 1.5 sq mm, and 6.0 mm auto cable can replace any
size up to 4.0 sq mm.
Caravan and Motorhome Books
Caravan and Motorhome
Books by Collyn Rivers
back to top

Lead
Acid Batteries
by Collyn Rivers
Batteries are
like teen-agers. They come in different shapes and sizes, some are
prone to sulking, others behave like (flawed?) angels, but by and
large their behavior reflects how they are treated.
Starter batteries, and deep cycle batteries work in a basically
similar way. Energy is stored within them as a result of an
electro-chemical reaction between lead plates and a water/acid mix
(called the electrolyte).
Charging is effected by
imposing a voltage across the battery that is greater than the
voltage ‘within’ that battery. The greater that voltage difference
the quicker and deeper the battery will charge. When battery voltage
reaches the charging voltage, charging ceases.
A starter battery
delivers a very heavy current (up to 400 amps). It does this
(hopefully) for only a few seconds. This discharges it by a mere
2%-3% and that small amount of energy is replaced within a minute or
two of the engine starting. In practice, starter batteries spend
most of their life somewhere between 65% and 70% of full charge.
Lead/calcium batteries may be charged a bit higher.
Providing such heavy
current requires the lead plates to present a large surface area to
the electrolyte. To enable this, starter batteries have a large
number of thin plates, but whilst this form of construction allows
heavy currents to flow for a few seconds, it will not withstand more
than a few extended discharges. Flatten most starter batteries half
a dozen times and they are dead
Deep Cycle Batteries
A deep cycle battery
differs from a starter battery in that it is intended to operate
consistently over a much large part of its capacity. It cannot
however supply remotely as heavy a current, in fact it will be
damaged if discharged regularly at greater than 25% or so of its
amp/hour capacity.
Despite their name,
deep cycle batteries cannot consistently provide remotely the energy
that the label on the side may lead you to believe. Without adequate
solar or ‘smart’ battery charging a deep cycle battery is unlikely
to exceed 70% of nominal charge. So there’s 30% lost up front.
Worse, battery makers advise not to discharge below 50%. As that
leaves only 20% for actual use almost everyone ignores the battery
makers’ advise and many people routinely run them down until the
lights go dim (about 80% discharged).
If treated as above,
the best deep cycle battery yet made is good for 80-100
charge/discharge cycles. If run down to about 30% remaining charge
they are good for 150-200 cycles. Doing as the makers advise gives
you 500-1000 cycles.
Sadly, magazine article
after another (and advertisers who should know better) routinely
claim a fridge that (for example) draws 5 amps will routinely run
for 20 hours on a 100 amp/hour battery. You’ll see pigs flying in
formation (whilst singing arias from Tosca) before a 100 amp/hour
battery can do that! The reality is that ‘deep cycle’ batteries
would better be described as ‘less-shallow cycle’ batteries.
How Low Should I Discharge?
Because the amount of
air shifted by a cooling fan is proportional to the cube of its
rotation, low voltage doesn’t do a great deal for fan-cooled motors,
but otherwise running the battery way down is unlikely to do any
harm. Most fridges have a voltage-sensing cutout that disconnects
the incoming power if it drops (typically) below 11.4 or so volts.
This is usually promoted as for protecting the battery, but its main
job is to protect the fridge motor from overheating.
Discharge level is
essentially a trade-off between convenience and your bank account,
but unless you keep the discharge to 65% (i.e. 35% left) you are
better off buying the cheaper traction batteries. These, and true
deep cycle batteries are likely to last about as long. But please do
not take the above as a recommendation to discharge batteries below
50%. I’m simply explaining what happens if you do.
A far better way is to
have a charging setup (which will generally require solar) such that
the batteries are routinely charged close to 100% and discharged
overnight by a probable 15-20%. This way the batteries stay much of
the time around 85%-90% fully charged – and last forever. That’s how
my OKA works and its last set of deep cycle batteries lasted over
seven years. (Just how to do this and why, is explained in my book
‘Solar That Really Works!’ I have published it in separate
‘Caravan’ and ‘Motorhome’ editions.
Microwave
Ovens - A Trap
Be aware that an
‘800-watt’ microwave oven may draw, via a 12-volt inverter, close to
150 amps. Such heavy current damage will damage any deep cycle
battery bank of less than 350-400 amp/hours.
Campervans and small
motorhomes commonly have microwave ovens, yet may have a battery of
only 150 amp/hr. If you use that microwave away from mains power, a
marine battery is a better bet. This is an exceptional
recommendation however as a marine battery’s capability, of
delivering light starter current yet retaining some deep cycle
characteristic, is of no benefit in normal use.
Knowing What’s Left
In a deep cycle
battery, especially when cold, the ‘charge’ held on the lead plates
massively leads what’s happening in the electrolyte. And vice versa.
This is because the electro-chemical reactions are very slow.
Because of this, any measurement of voltage taken within 12 hours of
charging or discharging is all but meaningless. All you are
measuring is the surface voltage of the plates.
Hence, a substantially
‘flat’ battery will present as close to fully charged (>12.6 volts)
for a long time after being fast charged for minute or two. And an
almost fully charged battery may present as near enough to ‘flat’
(<11.8 volts) after driving a microwave oven for a few minutes.
Despite this any camping
site will have people ‘checking’ batteries during the day and making
hugely incorrect assumptions on the basis of what they find. Even
doing this first thing in the morning, with absolutely everything
having been turned off overnight, may still result in 30% or more
error. Further one needs a very good meter to have the accuracy and
resolution to measure the critical 0.2 –0.3 volt in 12.7 or so
volts.
A hydrometer reading
is better – but the battery still needs to have rested. Take note
only of the hydrometer’s specific gravity reading, NOT of the
coloured bands and indications thereon. These markings usually
relate to starter batteries and indicate CHARGED at 1.280 SG or
more. A deep cycle battery is close to fully charged at an SG of
1.250 and is likely to be high as it will go by 1.260. Also, as
ambient temperatures rise, batteries charge at lower specific
gravities and voltages.
Measuring What’s Left
As a very rough guide,
a well-rested deep-cycle battery that shows 12.25 volts off-load is
about 50% charged. Full charge is likely to be 12.6-12.8 volts but
the slightest load may pull that down to 12.55 or lower. Table 1
gives a rough guide, but only after batteries have rested for at
least 12-hours.
The only really
effective way of knowing remaining charge is to measure what goes in
and what comes out and deduct charging losses. What’s left is more
or less what you’ve got. It’s actually a bit more complex than that
as the rate of charge/discharge affects the result. This was
thoroughly explained, via Peukert’s Equation, back in 1897 (email me
if you’d like a copy).
Almost every good solar
regulator costing over $300 or so shows what comes in and what goes
out, but do not necessarily include the Peukert correction (although
the Mastervolt unit does). Stand-alone energy monitors are also
available but if you are going to use solar it’s far cheaper to use
the functions provided by the more up-market solar regulators.
Sealed Batteries
Traditionally, the term
‘sealed battery’ described gel cells and, in recent years, AGM
(Absorbed Glass Mat) batteries. These batteries are heavier,
bulkier and costlier than conventional lead acid batteries. They
charge close to 100% via standard alternators and may be discharged
deeper with far less self-damage. They thus provide much closer to
100% of their nominal capacity and this compensates substantially
for their greater weight, bulk and cost.
In recent times the
term ‘sealed’ battery has also become a synonym for ‘low maintenance
battery’. These batteries use a small proportion of calcium, and
other things, in their plates to reduce gassing and water
consumption. That, plus a larger reservoir above the plates, enables
them to be permanently sealed. This seems a good ideas for starter
batteries (which have an intended life of only two/three years) but
I am not yet convinced of their suitability in deep cycle form –
where a well-maintained and correctly used conventional battery can
last five to seven years – unless you prefer to swap battery
longevity for freedom from checking the electrolyte level every
eight-twelve weeks.
Charging Batteries
A vehicle charging
system is deliberately designed to drastically cut back charging at
70% of full charge. The only really safe ways to approach 100%
charge (90% is a realistic target) is via adequate capacity solar
modules and solar regulator; or via a ‘smart’ charger – also
increasing known as a three-stage charger.
These latter chargers
are not cheap – they start at $300 or so – but so far most of their
vendors’ seem to have overlooked that a 10-amp smart charger will
charge a lead acid battery as fast as, and deeper, than any
chain-store 20-amp charger. Smart chargers may be left permanently
‘on’. If this is done the batteries will last many times longer.
Thus, despite their cost, smart chargers saves you money in the
medium-long term.
Like most things in
life , with batteries one tends to get back less than you put in –
about 15% of the charge/discharge cycle is lost in heat. This needs
to be remembered, but not always is, when installing solar.
Maintenance
Keep the terminals
clean externally (a tablespoon of bicarbonate of soda in a bucket of
water works like a charm). Once a year disconnect the terminals,
clean them until shiny on their contacting surfaces. After
reconnecting, coat with Vaseline or battery protection goo.
Check water levels at
least every eight–ten weeks. A correctly charging battery should
use some water. About one centimetre every ten weeks is normal in
temperate climates. If less the batteries are probably being
undercharged. If much more, and unless you are in a very hot area,
they are possibly being overcharged.
Avoid Christmas trees
of cables hung off battery terminals. Instead, install one or more
common power posts, and take a single heavy cable from there to the
battery terminal.
There’s a huge amount
more one can write about batteries (I know this because I already
have in Motorhome Electrics!) but the above gives a run down on the
more important aspects of their choice, care and feeding.
This article is published by
express permission of the copyright holder.
Please note that all
of Collyn Rivers’ published writing is protected under the
Commonwealth Copyright Act. No part may be produced in any form
without the written permission of the copyright holder (Caravan and
Motorhome Books, Broome WA).
See also my website
www.caravanandmotorhomebooks.com
|
Percentage Charge |
Voltage |
SG (<25 degrees) |
SG (>25 degrees) |
|
100% |
12.75 |
1.250 |
1.240 |
|
90% |
12.65 |
1.235 |
1.225 |
|
80% |
12.55 |
1.220 |
1.210 |
|
70% |
12.45 |
1.205 |
1.195 |
|
60% |
12.35 |
1.190 |
1.180 |
|
50% |
12.25 |
1.175 |
1.165 |
|
40% |
12.10 |
1.160 |
1.150 |
|
30% |
11.95 |
1.145 |
1.135 |
|
20% |
11.85 |
1.130 |
1.120 |
|
10% |
11.75 |
1.115 |
1.105 |
|
Zilch |
11.65 |
1.100 |
1.090 |
TABLE
1
Approximate voltages and
specific gravities of deep-cycle batteries (rested for at least 12
hours).
Copyright
2003 Caravan and Motorhome Books, Broome WA.
Caravan and Motorhome Books
Caravan and Motorhome
Books by Collyn Rivers
back to top

WHAT SOLAR MODULES REALLY PRODUCE
Solar
modules can and will only produce the output claimed by their
manufacturers if they are used in specific circumstances. Typical
trailer/motorhome usage is not one of them.
Outputs vary from type to type, but in typical
installations most solar modules produce a bit over 70% of their
apparently claimed output. Many modules have a small panel on their
rear face that shows what they actually produce. For an '80-watt'
module this is usually about 58 watts.
Whilst
this may seem misleading it is legally defendable. (The explanation
is included later in this piece).
Two Main Types of Module
There
are two main types of solar module: for the purpose of the first
part of this explanation they may be seen as Uni-Solar and the rest.
One type is not inherently better than the other. They simply have
different characteristics that cause them to be more effective in
some conditions than in others.
Most
solar modules produce less power as they heat up - as much as 20% in
seriously hot places like the north of Australia, and they start
losing this power from only a few degrees above freezing. Uni-Solar
uses a different technology that enables the modules to produce
slightly more power as temperature rises.
Because the power output of most solar modules
falls as they get hot, from around 35 degrees C (95 F) onward, a
64-watt Uni-Solar module produces much the same output as an 80-watt
most anything else. As they are about 15% cheaper in most countries
this can sometimes be a considerable benefit
Uni-Solar modules are also less affected by partial shadowing. If
most panels are shadowed by an area even as small as a human hand,
they lose virtually all of their output. Uni-Solar modules lose only
that area shaded.
No solar
module will work in complete shade. I need to spell that out because
after I stated (elsewhere) that solar modules produce a small output
under high-intensity full-spectrum light, this rapidly turned into 'Collyn
says they even work under street lights'. They don't.
The
above would appear to be an overwhelming argument for Uni-Solar.
This is not necessarily so. Their heat advantage is only really
worthwhile above 25 degrees C (77 F) or so. And a big downside for
many is that, because they are less efficient, they are much larger
(close to twice the area) of most large later. That's why I use
Solarex 80-watt modules on my OKA truck, and 28 by 64-watt Uni-Solar
modules on my 5 hectares at home.
In practice it is safe to assume that you will
get 58 watts from an 80-watt most-anything module, and about 55
watts from a 64-watt Uni-Solar module.
The
amount of energy you will capture each day can be readily worked out
by taking the true output of the modules (or about 72% of what it
says on the marketing brochure) and multiplying that by so-called
the Peak Sun Hours typical for where and when you are going. Maps
showing this can obtained from meteorological offices, but their's
need translating, and (for Australia) from all of my books. Peak Sun
Hours are explained below.
For
example, a single ‘120-watt’ module is likely to produce about 92
watts in most places. Broome has a typical six peak sun hours a day
(in summer) so the output there would be about 552 watt/hrs/day (or
about 42.5 amp/hrs/day).
Ideally solar modules should face the sun, but
flat roof mounting is surprisingly effective. Whilst modules can be
carried loose, they are readily stolen. In my experience it is not
worth arranging for tilting or tracking systems in latitudes less
than about 27 degrees. Adding about 20% more module capacity will
make up for any loss.
Heavy
cloud and rain cuts output by 50% or more. The highest output is
typically on bright days with scattered low cloud. Then, sun shines
down, is reflected from earth and bounced down again from those
clouds.
Because
most modules are heat-sensitive it pays to mount them so there's an
air space beneath. Less important with Uni-Solar but air space
provides useful heat insulation in the vehicle.
A solar
regulator is essential for all but systems where a very small solar
module (<20 watts) float charges a battery bank of at least 250
amp/hr. Even then I’d use one myself.
Technical Stuff
Solar
modules are tested using 'Standard Operating Conditions.'
The
output of solar modules is obtained by plotting curves of voltage
and current and from these using whatever combination of those two
parameters gives the highest 'number'. In practice this tends to
between 17.0 - 18 volts. Thus a module that produces 4.7 amps at 17
volts is rated at 80 watts.
Power being P = IV, that module will produce 56.4
watts at 12 volts - and 65.8 watts at 14 volts.
In other
words module output is a function of the voltage developed across
the load.
The
industry's 'Standard Operating Conditions' (SOC) measures output at
a cell (not ambient) temperature of 25 degrees C at an irradiance of
1 kW sq.m. As this equates to an ambient temperature close to 5
degrees C, the SOC may better be regarded as 'Standard Test
Conditions'.
Manufacturers do however also quote a separate
NOCT (Nominal Operating Condition Temperature).
This gives an indication of the actual cell
temperature at 20 degrees C ambient, but at 80% of the irradiance of
SOC operating conditions, a wind speed of 1 m.s, and the back of the
module enclosure open to atmosphere. Under these conditions the NOCT
is typically 47-49 degrees C. temperature - or looking at it another
way, the cell is likely to be 25-30 degrees C hotter than ambient
temperature.
Under
NOCT a typical 80-watt module produces about 59 watts.
Mono- and poly-crystalline modules lose output at
a rate of approximately 0.4%-0.5% per degree C above about 5 degrees
C (voltage drops considerably, current rises slightly). Thus at 30
degrees C ambient, output of modules using that technology is likely
to be 15% down (ie. over and above the loss due to working at 12-14
volts).
Amorphous technology modules tend to be increase output very
slightly with rising temperature.
The
current output of modules is usually shown in the technical data. It
may be shown as ISC (short circuit current), or as operating
current. The latter is the figure to use. True output wattage is the
operating current times the operating voltage. It must then be
corrected for temperature.
| Standard
Operating Conditions |
|
| Pmax (maximum
power) |
81.4 W. |
| Voc (voltage
open circuit) |
212 V. |
| Isc (current
short circuit) |
5.25 A. |
| VPmax (voltage
max power) |
16.60 V. |
| Ipmax (current
max power) |
4.9 A. |
| Normal
Operating Conditions |
|
| Pmax (maximum
power) |
59.0 W. |
| Ipmax (current
max power) |
4.0 A. |
This
is actual data from the rear panel of an 80-watt module.
Whilst
it is rare for modules to produce their full rated output (Pmax) it
is possible to achieve it (or very close to it) when driving a load
(such as a water pump) that will operate at the voltage at which
peak output was tested. It can also be achieved by using multi-point
tracking systems that, in effect act as 'electrical torque
converters'. They 'swap volts for amps' (actually a dc/dc convertion).
So whilst people tend to be confused by the rating system, it's both
technically credible and legal.
The term
Peak Sun Hours (PSH) is not my invention! It's used extensively in
the photo-voltaic industry but does not seem widely known by
engineers in other disciplines. In effect it's the number of hours
of midday sun on a clear day equivalent to the irradiation for that
day. One Peak Sun Hour equals 1 kilowatt/hour/square metre.
Full
details of what can be run from solar, required module and battery
capacity, installation (probably rather more than you wanted to
know!) are in my books - and in brief on my website,
www.caravanandmotorhomebooks.com
This article
is copyright Caravan and Motorhome Books, Broome 2004.
Email:
collynr@bigpond.com
It is reproduced by express permission.
Caravan
and Motorhome Books
All information has